AT&S

Aquastill - Project AT&S
Application
Printed Circuit Board.

Recovery of fresh water and gold from the PCB production by applying membrane distillation.

Key performance indicators: Manufacturing capacity: 250.000 m² PCB per year. Problem definition:
• - Variation in bath concentration during the operation
• - Loss of precious metals like gold and palladium.
Waste water streams: 100.000 m³ of waste water/a.

Advantages:
  • - Circular economy approach – no waste
  • - Recovery of valuable resources
  • - Use of waste heat
  • - Reduction of operating costs
  • - Reduction of environmental pollution
  • - Increase of company profit
Validated models will be used for future scenarios analysis and planning.

Actual Results: Signifi cant reduction of gold loss.

Location
Fehring, Austria

Year
2019

Capacity
Pilot plant
sustainable heat
desalinates water